30BTechnical Condition of Specified Devices • 15
Carrier Rail Properties
WAGO-I/O-SYSTEM 750
INTERBUS
Mechanical strength acc. to IEC 61131-2
Test specification Frequency range Limit value
5 Hz f < 9 Hz
1.75 mm amplitude (permanent)
3.5 mm amplitude (short term)
9 Hz f < 150 Hz
0.5 g (permanent)
1 g (short term)
IEC 60068-2-6 vibration
Note on vibration test:
a) Frequency change: max. 1 octave/minute
b) Vibration direction: 3 axes
15 g IEC 60068-2-27 shock
Note on shock test:
a) Type of shock: half sine
b) Shock duration: 11 ms
c) Shock direction: 3x in positive and 3x in negative
direction for each of the three mutually perpendicular axes
of the test specimen
IEC 60068-2-32 free fall 1 m
(module in original packing)
*) QP: Quasi Peak
Note
If the technical data of components differ from the values described here, the
technical data shown in the manuals of the respective components shall be
valid.
Komentarze do niniejszej Instrukcji